The fastest way to choose a belt scale is to look at the conveyor first. Your frame and idlers usually make the decision, and the add-ons follow from how the numbers will be used.
Weigh Shark® belt scales are designed and built by MCR Technologies Group in Sterling, Illinois. Davis Industrial distributes, installs and services them. Here's how the lineup fits together.
Every scale needs an integrator, and MCR's current model is the Weigh Shark 2. Highlights:
If you're running the original Weigh Shark — small screen and keypad — see the upgrade section below.
Standard Troughing (CEMA B, C, D). About 80% of what MCR sells. The weigh bridge is two separate assemblies, each with one load cell, bolted to each side of the conveyor frame. The idler's mounting feet are removed and the idler sits on the load cells. Standard load cells come in 150, 250 and 500 capacities. Single-idler accuracy is ±1%, with ½%, ¼% and ⅛% options by adding weigh bridges.
HD (CEMA E & F). A heavy-duty single-idler scale with four load cells and a heavy-duty mounting plate connecting the two assemblies. The idler mounts through a heavy-duty V-block, which eliminates torque from the idler sitting over the load cells.
Wing B & C. Built for portable plants, track stackers and other mobile equipment. Wing C mounts on C-channel frame supports; Wing B on side-discharge conveyors with tube frames. It's a bolt-on: no welding or cutting and no belt removal, with adjustable widths and calibration brackets attached. The model (C2 through C5) is selected by a single measurement — the "X dimension," bolt hole to bolt hole on the frame. One honest note: on portable equipment, accuracy can be lower depending on the load and installation.
CIT (Channel Insert Idlers). For conveyors using channel insert idlers. The bracket depends on the idler manufacturer, model and troughing angle, so those three details are required to quote.
Garland. For three- to five-roll idlers hanging from chain or cable. The scale bolts outside the frame and the chain attaches to the load cell — one of the simplest installs in the lineup.
kW Electric. A different approach entirely: it measures amp draw from the drive motor. No load cells, no speed sensor, no moving parts and no calibration weights. Installation takes about an hour by your electrician, and accuracy is rated at ±1%. A good fit where mounting a weigh bridge isn't practical.
Options across the line include stainless steel construction and low-temperature stainless load cells rated from −60°F to 125°F (standard load cells are temperature-compensated from 14°F to 122°F).
All speed sensors ship with 50 feet of cable; longer runs can be built at the factory before shipping.
These can be added at purchase or years later.
MCR stopped selling the original Weigh Shark control box new at the start of 2026, and replacement components are available only while supplies last. The WS1 → WS2 upgrade program converts your existing box to a Weigh Shark 2 for less than a new control box. Downtime runs about two to three days, so many plants buy one spare Weigh Shark 2, swap it in, send the old box for conversion and rotate it to the next conveyor.
Existing scales can also be upgraded in place: heavier load cells when the material changes, additional weigh bridges for tighter accuracy, and the heavy-duty speed sensor.
MCR keeps standard models in stock and ships within 24 hours, covers parts with a two-year limited warranty, and offers free call-in technical support.
Send us a completed belt scale application form — material, belt width and speed, idler type and spacing, maximum and minimum tons per hour, whether the angle changes, accuracy needed and power source — plus a photo of the idler and the stretch of conveyor you have in mind. We'll size it with MCR, recommend the location, and install it with the matched idlers it needs.
Ask your Davis rep for the application form, or schedule a free site walk at conveyors247.com · 813-247-3620.